Real-time control for transscleral cyclophotocoagulation.

1998

• Background: In transscleral cyclophotocoagulation, the surgeon cannot directly observe the applied laser effects. Overdosage, possibly resulting in unwanted pop effects, or underdosage with no therapeutic effect therefore often occur. • Method and materials: Laser radiation passing through the sclera and ciliary body is partly reflected from the fundus and can be monitored from outside the eye by a detector system. Since all other parameters influencing the intensity of the recorded radiation are constant in time during one laser exposure, the time dependence of this radiation directly reflects the change of transmission of the treated tissue. The laser exposure therefore can be stopped b…

AdultMalemedicine.medical_specialtygenetic structuresSwineGlaucomaFundus (eye)Signallaw.inventionCellular and Molecular NeuroscienceCiliary bodyPostoperative ComplicationslawTransmission curveOphthalmologymedicineCadaverAnimalsHumansAgedLaser Coagulationbusiness.industryCiliary BodyGlaucomaMiddle AgedLasermedicine.diseaseeye diseasesSensory SystemsIntensity (physics)ScleraOphthalmologymedicine.anatomical_structureTreatment OutcomeFemalesense organsSafetybusinessScleraGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

2014

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was…

PhysicsPhotonsPhotonbusiness.industryRadiotherapy Planning Computer-AssistedBrachytherapyMonte Carlo methodMonte Carlo method for photon transportGeneral MedicineSuperposition principleRadiation ProtectionOpticsTransmission curveElectromagnetic shieldingEmission spectrumbusinessMonte Carlo MethodBeam (structure)Medical Physics
researchProduct